EMS Platform

Industrial-Grade Energy Management System

Centralized local PLC control combined with remote cloud-connected visualization. Engineered for sub-100ms closed-loop dispatch optimization.

EMS CLOUD MONITORING · PROJECT: TAICHUNG-C&I-01 · REAL-TIME
LIVE
Battery SOC74%Cluster A+B avg
Grid Power82 kWImport
PV Generation145 kWActive
Battery Power63 kWDischarging

Power Flow Topology

☀️
145kWPV Solar
🏭
224kWC&I Load
🔌
82kWGrid
🔋
63kW · 74% SOCBESS System

Battery Cluster Status

74%

Cluster A

66%

Cluster B

Cell Min Temp

28.4°C

Cell Max Temp

31.2°C

Pack Voltage

748V

Cycle Count

312

Active Alarms3 Active
Battery Pack B03
High Temp Warning (Cell #12)
09:44:12
Critical
PCS Inverter #1
Reactive Power Deviation
09:35:01
Warning
HVAC System #2
Filter Maintenance Due
09:12:44
Info
Device Status
PCS Inverter #1
Running
BMS Cluster A
Charging
BMS Cluster B
Standby
PV Inverter #1
Generating
Grid Meter
Online
HVAC System
Active
Cloud Infrastructure

Centralized Web Monitoring

The cloud monitoring platform aggregates multi-site operational data. Access comprehensive battery status, power flow trends, device performance indicators, and automated reporting curves from any device.

Key Indicators

SOC/SOH, cumulative charge/discharge, PV generation, grid active power, phase data.

Automated Reports

Generate structured daily, monthly, and annual energy balance and health analysis sheets.

Live Power Flow Simulator

Interactive Energy Dispatch Routing

Our cloud platform provides real-time single-line visual topologies. Click the operational strategy presets below to simulate how the system routes electricity paths dynamically.

Active Mode Analysis: PV solar generation powers the industrial load. Excess PV energy is routed to charge the battery. Grid import is minimized.

Solar PVActive
C&I LoadConsuming
BESS SystemCharging
Gateway
Utility GridZero Export
Active Alarm Management System

Dynamic Color-Coded Alarm Severity

Telemetry triggers active alarms mapped to three priority levels: Critical, Warning, and Informational. Operators can query, acknowledge, filter, and close warnings immediately to safeguard project hardware.

Critical (Immediate shutdown / Fire protection)
Warning (Condition out of range)
Active Alarm Queue3 Pending Actions
09:44:12Battery Pack B03

High Temperature Warning (Cell #12)

Critical
09:35:01PCS Inverter #1

Reactive Power Deviation Alert

Warning
09:12:44HVAC System #2

Filter Maintenance Interval Approached

Info
Get Started

Build Smarter Energy Infrastructure

Speak with our energy systems specialists about your next BESS deployment, EMS integration, or critical infrastructure project.